Home About Us Writing a Scientific Article Author's Instruction Contact us
 

MERIT RESEARCH JOURNAL OF ENVIRONMENTAL SCIENCE AND TOXICOLOGY (MRJEST) (ISSN: 2350-2266)

 
 

/  /    MRJEST Home   /   /    About MRJEST    /  /    Submit Manuscripts    /  /      Call For Articles      / /     Editorial Board     / /    Archive     / /    Author's Guide  /  /

 
 


July 2015 Vol.3 No.6

Other viewing option


Abstract
• Full text
•Reprint (PDF) (529 KB)


Search Pubmed for articles by:
 

Thareja S
Trivedi P

Other links:
PubMed Citation
Related articles in PubMed




 










 

Merit Research Journal of Environmental Science and Toxicology (ISSN: 2350-2266) Vol. 3(6) pp. 072-078, July, 2015

Copyright © 2015 Merit Research Journals

Original Research Article

Evaluation of Air Quality: Air Pollutants of air at Kanpur by using Correlation Study

 
 
 

Sukarma Thareja1*, Manju Gupta2 and Priyanka Trivedi1

 

1CSJM Kanpur University, Kanpur, UP, India, Department Of Chemistry, Ch. Ch. College, Kanpur,UP,India
2CSJM Kanpur University, Kanpur, UP, India, Pollution Control Board, UP, India

*Corresponding Author’s E-mail: sukarmathareja@hotmail.com

Accepted April 13, 2015

 

Abstract

 

We present an extensive investigation of pollutants respirable suspended particulate matter (RSPM) and suspended particulate matter (SPM), oxides of nitrogen (NOx), sulphur dioxide (SO2) of Kidwai Nagar (S1), Darshanpurva (S2), Panki site (S3), Shastri Nagar (S4), Awas Vikas (S5) Meteorological parameters (temperature, relative humidity, wind speed and rainfall) present in air samples of Kanpur for Jan -2010 to Dec-2011. Each air pollutant is marked with a subscript k,d,p,s,a representing the name of area from which it belong to. In the present study, it was noticed that the observed values of SPM and RSPM levels at all selected stations exceeds the standard limits recommended by Central Pollution Control Board (CPCB) New Delhi, India. SO2 and NOx levels in residential, industrial and commercial areas remain under recommended limits of CPCB. Correlation coefficients were calculated between different pairs of pollutants and Meteorological parameters. To identify the highly correlated and interrelated air quality parameters, t-test was applied for checking significance. Pollutants RSPM and SPM show significant positive correlations with p<0.01. An appreciable significant positive correlation have been found for RSPMk with SPMk, RSPMd, SPMd, RSPMp, SPMp, Noxp, SPMs and SPMa. A significant positive correlation was also found between wind speed and relative humidity. Relative humidity bears negative correlation with RSPMp, SPMp, RSPMs and SPMs Similarly rain fall also shows negative correlation with RSPMk, SPMk, RSPMd, SPMd, RSPMp, SPMp and SPMs.

Keywords: Air pollutants, Pollutants, Respirable Suspended Particulate Matter (RSPM), Suspended Particulate Matter (SPM), t-test

















 

 
 
   
   
   
   
   
   
   
   
   
   
   
 
 
 
 
 
 
 
 
   
 
                         

Merit Research Journals© 2016 || Advertisement | Privacy policy.